LANDTEC GEM 5000 Landfill Gas Analyzer

LANDTEC GEM 5000 Landfill Gas Analyzer for sale, lightly used year 2013, everything is still excellent full working order condition

$2,500

LANDTEC GEM 5000 Landfill Gas Analyzer for sale, lightly used year 2013, fully shop tested,everything still in excellent perfect and flawless condition, been checked, tested ready to work, is in full working order plus includes the case & accessories.  

Package Includes:

  • LANDTEC GEM 5000
  • Hoses
  • Heavy duty water trap filer
  • Soft case
  • A.C. battery charger
  • Electronic Manual accompanies software
  • LANDTEC System Gas Analyzer Manager (LSGAM) software
  • USB download cable and hard-case

GPS & Enterprise option enabled.

Applications:

  • Landfill Gas Collection & Control Systems
  • Environmental Compliance
  • Landfill Gas to Energy
  • Subsurface Migration Probes

Reads: Methane, Carbon Dioxide, Oxygen, Temperature (when used with optional probe), Atmospheric pressure, Differential pressures, Calculates gas flow

LANDTEC GEM 5000 PORTABLE GAS ANALYZER

The LANDTEC GEM 5000 is designed specifically for use on landfills to monitor Landfill Gas (LFG) collection and control systems. The GEM  5000 samples and analyzes the methane,carbon dioxide and oxygen content of landfill gas with options for additional analysis.

FEATURES

  • Measures % CH4, CO2 and O2 Volume, static pressure and differential pressure
  • Calculates balance gas, flow (SCFM) and calorific value
  • High accuracy and fast response time
  • Lighter and more compact
  • Certified intrinsically safe for landfill use
  • Calibrated to ISO/IEC 17025
  • CO and H2S (on Plus models only)
  • 3 Year warranty
  • Annual recommended factory service
  • Available with GPS and additional gas detection

BENIFITS

  • Designed specifically for use on landfills to monitor landfill gas (LFG) extraction systems, flares, and migration control systems.
  • No need to take more than one instrument to site
  • Can be used for monitoring subsurface migration probes and for measuring gas composition, pressure and flow in gas extraction systems
  • The user is able to set up comments and questions to record information at site and at each sample point
  • Ensures consistent collection of data for better analysis
  • Streamlined user experience reduces operational times

APPLICATIONS

  • Landfill Gas Collection & Control Systems
  • Environmental Compliance
  • Landfill Gas to Energy
  • Subsurface Migration Probes
GEM 5000 MODELS
Model Meter with AC Charger – No Kit
5000 CH4, CO2, 02, static and differential pressure
5000+ Adds CO (0-2000 ppm), and H2S (0-500 ppm)
5000+1 Adds CO (0-2000 ppm), and H2S (0-1000 ppm)
5000+5 Adds CO (0-2000 ppm), and H2S (0-5000 ppm)
5000+10 Adds CO (0-2000 ppm), and H2S (0-10000 ppm)
5000Nav Adds Built-in GPS
5000Nav+ Adds Built-in GPS, CO (0-2000 ppm), and H2S (0-500 ppm)
5000Nav+1 Adds Built-in GPS, CO (0-2000 ppm), and H2S (0-1000 ppm)
5000Nav+5 Adds Built-in GPS, CO (0-2000 ppm), and H2S (0-5000 ppm)
5000Nav+10 Adds Built-in GPS, CO (0-2000 ppm), and H2S (0-10000 ppm)
GM5K-Kit GEM 5000 Kit Includes: Hoses, heavy duty water trap filter, soft case, electronic manual accompanies software, LANDTEC System Gas Analyzer Manager (LSGAM) software, USB download cable and hard-case.

GEM 5000 SPECIFICATIONS

GASES RANGE
Gases Measured


 
CH4 By dual wavelength infrared cell with reference channel
CO2 By dual wavelength infrared cell with reference channel
O2 By internal electrochemical cell
CO By internal electrochemical cell
H2S By internal electrochemical cell
Ranges



 
CH4 0-100% (vol)
CO2 0-100% (vol)
O2 0-25% (vol)
CO 0-2000 ppm***
H2S 0-500 ppm***
Gas Accuracy* CH4 0-5% ±0.3% (vol) 0-70% ±0.5% (vol) 70-100% ±1.5% FS
CO2 0-5% ±0.3% (vol) 0-60% ±0.5% (vol) 60-100% ±1.5% FS
O2 0-25% ±1.0% (vol)
CO (H2)** 0-2000 ppm ±1.0% FS
H2S 0-500 ppm ±2.0% FS
* Typical accuracy after calibration as recommended in the operations manual.
** Hydrogen compensated Carbon Monoxide measurement.
*** Additional ranges available, call for more information
OTHER PARAMETERS
  Unit Resolution Comment
Energy BTU/hr 1000 BTU/hr Calculated from specific parameters
Static Pressure in. H2O 0.1 in. H2O Direct Measurement
Differential Pressure in. H2O 0.001 in. H2O Direct Measurement
Important Note: The information in this document is correct at the time of generation. Specification may change without prior notice as a result of continuing development
PUMP  
Flow Typically 550cc/min.
Flow with 80 in. H2O vacuum Approximately 80cc/min.
ENVIRONMENTAL CONDITIONS
Operating Temperature Range 14°F–122°F (-10°C–50°C
Operating Pressure 100 in. H2O, +100 in. H2O (-250 mbar, +250 mbar)
Relative Humidity 0-95% non-condensing
Barometric Pressure ±14.7 in. Hg (±500 mbar) from calibration pressure
Barometric Pressure Accuracy ±1% typically
POWER SUPPLY
Battery Life Typical use 8 hours from fully charged
Charge Time Approximately 4 hours from complete discharge
CERTIFICATION RATING
ATEX II 2G Ex ib IIA T1 Gb (Ta= -10°C to +50°C)
ISO17025 ISO/IEC17025:2005 Accreditation #66916
CSA Ex ib IIA T1 (Ta= -10°C to +50°C) (Canada), AEx ib IIA T1 (Ta= -10°C to +50°C) USA

Landtec-GEM-5000-Portable-Gas-Analyzer.pdf